Lapp OLFLEX HEAT 1565
Glass fibre insulated power cable
- Can Withstand temperatures up to +400 °C (short term +1565°C)
- Low conductor-resistance due to the nickel-plated copper conductors
- Able to withstand temporary contact with molten metal or glass
- Fine-wire strand made of nickel-plated copper
- MICA tape wrapping and impregnated glass fibre braiding
- Cores twisted together
- Outer sheath: MICA tape-wrapping, impregnated glass fibre braiding, red
- Flame-retardant
- Halogen-free
- Only suitable for use in dry conditions
Application range
- Guarantees the circuit even in areas with extremely high ambient temperatures
- Blast furnaces and coking plants
- Refineries
- Glassworks
- Aluminium and steelworks
-
30016600 | ÖLFLEX HEAT MC 1565 4X1,5 | Glass Fibre CableGlass fibre insulated power cable, Number of Conductors: 4, Conductor Cross Section: 1.5mm², Nominal Voltage: U0/U: 300/500 V
-
30016603 | ÖLFLEX HEAT MC 1565 2X1,5 | Glass Fibre CableGlass fibre insulated power cable, Number of Conductors: 2, Conductor Cross Section: 1.5mm², Nominal Voltage: U0/U: 300/500 V
-
30016606 | ÖLFLEX HEAT MC 1565 4X1 | Glass Fibre CableGlass fibre insulated power cable, Number of Conductors: 4, Conductor Cross Section: 1.0mm², Nominal Voltage: U0/U: 300/500 V
-
30016609 | ÖLFLEX HEAT MC 1565 2X1 | Glass Fibre CableGlass fibre insulated power cable, Number of Conductors: 2, Conductor Cross Section: 1.0mm², Nominal Voltage: U0/U: 300/500 V
-
30020808 | ÖLFLEX HEAT MC 1565 2X0,5 | Glass Fibre CableGlass fibre insulated power cable, Number of Conductors: 2, Conductor Cross Section: 0.5mm², Nominal Voltage: U0/U: 300/500 V
-
30020809 | ÖLFLEX HEAT MC 1565 2X0,75 | Glass Fibre CableGlass fibre insulated power cable, Number of Conductors: 2, Conductor Cross Section: 0.75mm², Nominal Voltage: U0/U: 300/500 V
-
30020810 | ÖLFLEX HEAT MC 1565 2X2,5 | Glass Fibre CableGlass fibre insulated power cable, Number of Conductors: 2, Conductor Cross Section: 2.5mm², Nominal Voltage: U0/U: 300/500 V
-
30020811 | ÖLFLEX HEAT MC 1565 2X4 | Glass Fibre CableGlass fibre insulated power cable, Number of Conductors: 2, Conductor Cross Section: 4.0mm², Nominal Voltage: U0/U: 300/500 V
-
3013234 | ÖLFLEX HEAT SC 1565 1X1,5 | Single Core CableGlass fibre insulated single core cable, For use in blast furnaces, glassworks etc, Conductor Cross Section: 1.5mm², Cable Outer Diameter: 3.3mm
-
3016697 | ÖLFLEX HEAT SC 1565 1X10 | Single Core Cable
Glass fibre insulated single core cable, For use in blast furnaces, glassworks etc, Conductor Cross Section: 10.0mm², Cable Outer Diameter: 6.2mm
-
3016698 | ÖLFLEX HEAT SC 1565 1X16 | Single Core CableGlass fibre insulated single core cable, For use in blast furnaces, glassworks etc, Conductor Cross Section: 16.0mm², Cable Outer Diameter: 7.9mm
-
3016699 | ÖLFLEX HEAT SC 1565 1X25 | Single Core CableGlass fibre insulated single core cable, For use in blast furnaces, glassworks etc, Conductor Cross Section: 25.0mm², Cable Outer Diameter: 9.2mm